The MISLIER CDN vertical multistage centrifugal pump brings a key upgrade to conventional CDLF-style pumps: fully welded impellers are standard across the entire CDN series, alongside higher-head performance.
Built with stainless steel hydraulic components and a compact vertical configuration, the CDN series serves clean-water supply, pressure boosting and industrial water systems. Its wide model range helps you match the pump to your required flow rate, head and installation conditions.
What Makes the CDN Series Different?
Fully Welded Impellers in Every Model
Every CDN model uses fully welded impellers. This construction is a standard feature throughout the range, giving buyers a clear specification when selecting pumps for different flow requirements.
Whether you need a small-flow booster pump or a larger model for an industrial water system, the CDN series maintains the same commitment to fully welded impeller construction.
Higher Head for Pressure-Demanding Systems
The CDN series offers higher head than conventional CDLF-style vertical multistage pumps, making it an option for projects with greater pressure requirements.
For buyers evaluating a CDLF alternative, the CDN series deserves consideration when available head is a key selection factor. Compare the performance curves at your required flow rate to identify the right model and number of stages.
Compact Vertical, In-Line Design
The inlet and outlet share the same horizontal centerline, supporting in-line pipe installation. The vertical multistage layout keeps the installation footprint compact while accommodating multiple pumping stages.
Stainless Steel Hydraulic Components
Stainless steel impellers, guide vanes and other key hydraulic components support clean-liquid pumping applications. AISI 304 and AISI 316L options are listed for selected components, subject to the specified configuration.
Material selection should be matched to the pumped liquid and operating conditions.
Applications for the CDN Vertical Multistage Pump
Water Supply and Pressure Boosting
Use the CDN series for clean-water transfer and pressure boosting in building and industrial water supply systems. It can operate as an individual booster pump or be integrated with control equipment into a constant-pressure water supply system.
Industrial Water Systems
For industrial installations requiring clean-liquid transfer at higher head, the CDN range offers multiple flow classes, stage configurations and motor sizes.
Integrated Booster Systems
The compact in-line configuration supports integration into packaged booster systems. Select the pump and control arrangement according to the required duty point and system operating strategy.
Technical Specifications
| Item | Specification |
|---|---|
| Pump type | Vertical multistage centrifugal pump |
| Series | CDN / CDNF |
| Impeller construction | Fully welded impellers across the entire CDN series |
| Rated flow classes | 1, 2, 3, 4, 5, 8, 10, 12, 15, 16 and 20 m³/h |
| Overall flow range | 0.4–28 m³/h, depending on model |
| Motor power range | 0.37–22 kW, depending on model |
| Standard liquid temperature | −15°C to +70°C |
| Hot-water version liquid temperature | −15°C to +105°C |
| Maximum ambient temperature | +40°C |
| Installation altitude | Up to 1,000 m |
| Motor protection | IP55 |
| Motor insulation | Class F |
| Motor design | Enclosed, fan-cooled IEC motor |
| Connection options | Flange, threaded and other configurations, depending on model |
Ranges cover the series and do not represent one pump’s combined operating capability. Confirm the selected model’s performance curve, pressure rating, materials and temperature limits before ordering.
CDN vs. Conventional CDLF-Style Pumps
The CDN series stands out through two core product features: fully welded impellers throughout the range and higher-head performance.
When comparing a CDN pump with a conventional CDLF-style model, review the actual specifications at the required duty point. Impeller construction, flow rate, head, motor power, materials and connection dimensions all matter when choosing a suitable pump.
Share your existing CDLF model and operating requirements with us to evaluate a CDN alternative.
Frequently Asked Questions
Do all CDN pumps use fully welded impellers?
Yes. Fully welded impellers are standard across the entire CDN series.
What is the main advantage of CDN compared with conventional CDLF-style pumps?
The CDN series combines fully welded impellers across all models with higher-head performance. The exact head difference depends on the models and operating points being compared.
Is the CDN series suitable for constant-pressure water supply?
Yes. CDN/CDNF pumps can be connected to suitable control equipment to form a constant-pressure water supply system.
What liquids can the pump handle?
The series is intended for thin, clean, non-flammable and non-explosive liquids without solid particles or fibers. Confirm liquid compatibility with the selected materials and seals.
Can the CDN pump handle hot water?
A hot-water version is listed for liquid temperatures from −15°C to +105°C. Specify the required temperature when requesting a quotation so the appropriate configuration can be confirmed.
How do I select the right CDN model?
Provide your required flow rate, total head, liquid type, liquid temperature, power supply and connection requirements. These details allow the model, stage count and motor rating to be matched to your application.
Find the Right CDN Pump for Your Project
Looking for a high-head vertical multistage centrifugal pump with fully welded impellers?
Send us your operating requirements or existing pump specifications. We will help you select a suitable CDN model and provide the relevant performance curve, technical details and quotation.
Contact Us for Pump Selection and a Quote